Every controlled environment is an energy system. AI forecasts it, plans it and trades its flexibility, inside the limits you set.
Illustrative winter weekday, 1 ha lit glasshouse, 1 MW of PV. Its flexibility is the crop's dark period, which the plan may place. Without a battery, it covers the evening peak, 16:00 to 22:00, and the lights run on cheaper, cleaner power.
£440 and 115 kg of CO₂ saved by going dark at the peak. Grid carbon: NESO, January 2026 weekdays, CC BY 4.0.
With a battery, the dark period stays where the crop needs it, 20:00 to 02:00. The battery charges on cheaper, cleaner night power and carries the lights through the peak.
£430 and 100 kg of CO₂ saved by the battery. Grid carbon: NESO, January 2026 weekdays, CC BY 4.0.
Glasshouses, vertical farms, container and mushroom farms each draw power their own way. One model learns each, hour by hour and season by season.
86% of the year's energy falls between October and March.
Every month is within 4% of the yearly average. The dark period can sit at any hour.
Without a battery, the lights move to the cheapest hours and the dark period covers the evening peak. With one, the lights run when the crop needs them and the battery carries the peak.
Without a battery, the dark period's timing moves the day's cost by up to £570. With one, by up to £260.
Without a battery, the dark period's timing moves the day's cost by up to £590. With one, by up to £280.
Illustrative: 1 ha lit glasshouse, grey and mild January weekday. 640 kW of LED lighting (64 W/m²), 1 MW of solar PV, heat-pump heating, 15–40 kW of pumps, fans and packing. Half-hourly tariff: night rate, day rate and a 16:00–19:00 red band. Battery: 1 MW, 3 MWh, 10% reserve, within 1.2 MW import capacity.
Illustrative: 5,000 m² vertical farm, grey and mild January weekday. 400 kW of LED lighting (80 W/m²), cooling that follows the lights, 40–60 kW of pumps, fans and packing. Half-hourly tariff: night rate, day rate and a 16:00–19:00 red band. Battery: 750 kW, 2.2 MWh, 10% reserve, within 900 kW import capacity.
Sun, cold and damp air change the load hour by hour. The forecast tracks the weather at the site, and the plan updates every 5 minutes.
Moving power out of the dearest hours cuts the bill. The move itself is also worth money: markets pay for power left untaken when the grid is short, and for power taken when it has plenty.
Power left untaken is sold in the wholesale market, priced on EPEX and settled by Elexon under P415. The supplier and the tariff stay the same.
NESO's Demand Flexibility Service pays for load that steps back when the system is short, and for load that steps up when wind has nowhere to go. The lights can do either, inside the crop's daily light.
Local cables fill up on winter evenings. The network operator pays sites that keep clear of them, so more can connect without new cables.
Illustrative: 1 ha lit glasshouse, the plan without a battery, against lights on the crop's own schedule. A meter trades through P415 or through NESO's service, not both. For lighting, all three are in development.
You set the limits. Every plan stays inside them, recalculated every 5 minutes. The climate computer keeps running the crop.
Growers of every kind, and the companies that light, cool and power them.